<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T05:09:15Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.0113d" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.0113d</identifier>
    <datestamp>2026-09-20T15:18:18Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-09-20</dc:date>
  <dc:title>Nano Research-Coalescence Angle-Driven 1T-to-1H Phase Transition in Monolayer TaS₂</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.0113d</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Original information of the core experimental data presented in the article: these are standard datasets acquired by Omicron scanning tunneling microscopy (STM). Complete experimental information and measurement conditions can be accessed when the files are opened with the corresponding dedicated software.Z: Z-axis topography channel, which outputs the height information of the sample surface as the measurement signal.RetraceDown: Retrace scanning in the downward direction along the Z-axis. It serves as a control counterpart to forward scan data, and is used to eliminate imaging artifacts caused by scan drift and piezoelectric hysteresis.Tue Nov 15 01.51.40 2022: The precise timestamp of data acquisition (accurate to the second), applied for experimental traceability, batch management and replicate verification.[5-1]: Batch identifier of the scanning experiment.STM: Indicates that the data is generated via scanning tunneling microscopy.</dc:description>
  <dc:subject>Coalescence Angle; TaS₂; Phase Transition</dc:subject>
  <dc:creator>Guo Zhiqiang</dc:creator>
  <dc:creator>Tang Shujie</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>