<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T02:52:19Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.02290" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.02290</identifier>
    <datestamp>2022-11-24T15:35:59Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2022-11-24</dc:date>
  <dc:title>Data for Paper &amp;quot;Microwave response of the chiral helimagnetic MnNb3S6&amp;quot;</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.02290</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Single-crystals of MnNb3S6 were grown by the chemical vapor transport (CVT) method. The powders of Mn, Nb, and S in high purity (99.9 %) were sealed in silica tube, which was heated to 800 ◦C. The two ends of the tube are kept at 800 ◦C and 950 ◦C respectively for several days. The I2 was used as the transport gas. The sample preparation method, chemical compositions, determination of crystal orientations were described in details elsewhere [1]. The magnetization was measured using a Quantum Design vibrating sample magnetometer (SQUID-VSM). The ESR spectra were carried out using a Bruker EMX plus model spectrometer operating at X-band frequencies (9.4 GHz). The applied magnetic field was rotated from the ab-plane to the c-axis. To ensure a precise magnetic field and data, the magnetic field was applied with no-overshoot mode, and relaxed for 2 minutes before data collection. The ESR spectra were collected at selected temperatures, where the variation of temperature was performed by a helium continuous flow thermostat.&amp;nbsp;</dc:description>
  <dc:subject>Microwave response; chiral helimagnetic ; MnNb3S6</dc:subject>
  <dc:creator>Lei Zhang</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nc-sa/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>