<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T04:27:35Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.03762" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.03762</identifier>
    <datestamp>2022-10-17T13:48:47Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2022-10-17</dc:date>
  <dc:title>Deuterium plasma-driven permeation through vanadium, niobium and tantalum membranes</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.03762</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Deuterium (D) plasma-driven permeation (PDP) experiments for vanadium (V), niobium (Nb) and tantalum (Ta) membranes are performed between 573&amp;ndash;873 K in the linear plasma facility PREFACE. The sample temperature, membrane thickness and ion incident energy effects on D permeation behavior through these three metals are studied. PDP fluxes of D through Ta and Nb decrease with decreasing sample temperature, except for the 0.05 mm thick Nb case. Moreover, a break point around 750 K can be observed on the flux-temperature curves for all V samples. The D PDP flux through Nb decreases as the thickness increases. For Ta and V samples, however, the permeation fluxes do not change significantly when their thicknesses are thinner than 0.1 mm. A drop in D permeation fluxes for the three materials is observed when increasing the ion incident energy. The surface morphology is checked by Scanning Electron Microscopy (SEM). Only the V membranes exposed to D plasma show surface exfoliation.</dc:description>
  <dc:subject>Hydrogen isotope separation; Plasma-driven permeation; Super-permeation</dc:subject>
  <dc:creator>Lu WANG</dc:creator>
  <dc:creator>Hai-Shan ZHOU</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>