    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2022-10-26</dc:date>
  <dc:title>A compact electron beam ion trap in support of high-temperature plasma diagnostics based on conduction-cooled superconducting coils</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.04581</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Spectroscopic diagnostics of future fusion reactor plasmas require information on impurity line emissions, especially for relevant high Z metal elements (e.g., tungsten). These materials will be widely used as plasma facing components for their high heat tolerance and low sputtering yield. Based on an electron beam ion trap, a compact impurity spectra platform is developed to mimic the high temperature environment of a fusion reactor. The proposed platform can deliver a focused e-beam at energies over 30 keV using a confining magnetic field of 1.0 T generated by two superconducting coils (NbTi). Cooled by a closed-loop cryocooler, the coils can avoid the usage of a complicated cryogenic system involving the handling of liquid helium. For spectroscopic studies of highly charged ions, a spherically curved crystal spectrometer is proposed to measure a wavelength range around 2&amp;ndash;4 &amp;Aring; covering the typical wavelength range expected to be emitted by metal ions in a fusion plasma. This paper reports the design and development progress of the platform.</dc:description>
  <dc:subject>Spectroscopic diagnostics;  plasma; electron beam ion trap; conduction-cooled superconducting</dc:subject>
  <dc:creator>Bin Bin</dc:creator>
  <dc:creator>Bo Lyu</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1063/5.0040620</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>