<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T06:03:26Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.06463" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.06463</identifier>
    <datestamp>2022-11-18T14:18:58Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2022-11-18</dc:date>
  <dc:title>Data Set of Major Element of Red Sandstone Tafoni Samples in Danxiashan</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.06463</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>The major element analysis of 3 tafoni interior surface powder samples and 1 original sandstone powder sample was conducted on Agilent 720 inductively coupled plasma emission spectrometer (ICP-OES). During the experiment, about 0.05g of powder sample was placed in a PTFE container, and 0.6 ml HF and 3 ml HNO3 were added. Then the sealed container was placed in an electric furnace and heated to 185 &amp;deg; C for about 36h. After cooling, heat the container on the hot plate and allow it to evaporate to dryness, then add 200 ng Rh as the internal standard, then add 2 ml HNO3 and 4 ml water. Seal the container again and place it in an electric furnace at 135 &amp;deg; C for about 5h to dissolve the residue. After cooling, it is measured by ICP-OES with dilution factor of 1000. The sample was digested by alkali fusion method to determine the content of silicon dioxide. Dissolve 0.05 g of sample in a silver crucible with 0.25 g NaOH at 700 &amp;deg; C for about 30 min. After cooling, dissolve with hot water and acidify with 5 ml HCl, and finally add water to 250 ml for ICP-OES measurement. About 1g sample is used for LOI. The sample is weighed in a porcelain crucible and heated in a muffle furnace at 900 ℃ for about 1 hour. The weight difference before and after ignition is LOI.</dc:description>
  <dc:subject>Danxiashan; Red Sandstone; Tafone; Major Element</dc:subject>
  <dc:creator>Jintao Hu</dc:creator>
  <dc:creator>Zhijun Yang</dc:creator>
  <dc:creator>Wang He</dc:creator>
  <dc:creator>Hengheng Du</dc:creator>
  <dc:creator>Ke Zhang</dc:creator>
  <dc:creator>HongWei Li</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/publicdomain/zero/1.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>