<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T20:02:18Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.07413" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.07413</identifier>
    <datestamp>2023-02-14T17:13:17Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-02-14</dc:date>
  <dc:title>Data of Characterization of ion transmission in UV-FAIMS by incorporating ion recombination</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.07413</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Device: home-made FAIMS;Method: The flow meter with specifications of 0&amp;ndash;1000 L/h ensured a wide range of adjustable conditions. The signal was collected using a data acquisition card (NI USB-6009, National Instruments Corp.) connected to the LabVIEW software to show the FAIMS data in real time. Some important FAIMS parameters are shown as follows: Ionization source is UV lamp (10.6 eV), dispersion voltage (DV) changes in 0&amp;ndash;1500 V, compensation voltage (CV) changes in -30 to +30 V, sample components are N2 and gaseous sample (99.95%).&amp;nbsp;&amp;nbsp;Experiment 1:Changing the gas flow rate from 0 to 800 L/h and the concentration from 10 ppb to 100 ppm using ammonia, acetone, and 1,3-butadiene samples.Experiment 2:First, the DV was examined using ammonia at a mixing ratio of 0.5 ppm, and secondly, the gas flow rate at a DV of 200 V using ammonia at a mixing ratio of 0.5 ppm.Date: 2017/11/9-2017/11/30</dc:description>
  <dc:subject>FAIMS; ion recombination;  ion loss</dc:subject>
  <dc:creator>Han Wang</dc:creator>
  <dc:creator>Chilai Chen</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>