<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T23:08:54Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.08256.sdb" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.08256.sdb</identifier>
    <datestamp>2023-05-13T17:02:32Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-05-13</dc:date>
  <dc:title>The date of Mo1Sn20</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.08256.sdb</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>The evaluation process of methanol oxidation to methylal reaction is carried out on an atmospheric pressure continuous flow fixed bed reactor. During the experiment, a 1.5 mL ceramic ring (20-40 mesh) was used to dilute 0.5 mL (20-40 mesh) of catalyst. Before the reaction, the reaction tube is programmed to heat up and the catalyst is pre-treated with oxygen. When the temperature rises to 300 &amp;deg; C, the catalyst is activated by maintaining a constant temperature in an oxygen atmosphere for 2 hours. Afterwards, it is cooled to a reaction temperature of 140 &amp;deg; C and methanol is slowly introduced. The ratio of methanol to oxygen during the reaction process is 1:9.415 (molar ratio), with a volumetric space velocity of 7200 h-1, and the flow rate of the exhaust gas is detected.&amp;nbsp;X-ray diffraction (XRD) testing was conducted on the MiniFlex 600 X-ray diffractometer from Rigaku Corporation in Japan, using Cu K &amp;alpha; Radiation irradiation, with a scanning angle of 5-90 &amp;deg; and a continuous scanning rate of 4 &amp;deg;/min.&amp;nbsp;The programmed temperature desorption (NH3-TPD) test was conducted on the TP 5080 chemical adsorption instrument. Weigh 100 mg of catalyst and place it in a sample tube. Heat it up to 400 &amp;deg; C in an inert atmosphere with a gas flow rate of 30 mL/min, then cool it down to 50 &amp;deg; C. Introduce NH3 (30 mL/min) for adsorption for 10 minutes, then blow it out. Finally, heat it up to 600 &amp;deg; C for desorption and record the signal.&amp;nbsp;The programmed temperature reduction (H2-TPR) test was conducted on the TP 5080 chemical adsorption instrument. Weigh 100 mg of catalyst and place it in a sample tube, program the temperature to 200 &amp;deg; C, and then cool it down to 50 &amp;deg; C. Then, the mixed gas is introduced and the temperature is programmed to 900 &amp;deg; C to reduce the catalyst, and the signal is recorded.&amp;nbsp;The N2 physical adsorption and desorption test was conducted on a Japanese Bayer (BEL) BELSORP-MAX II instrument, and the catalyst sample was subjected to degassing pretreatment at 200 &amp;deg; C. Then, a low-temperature N2 adsorption and desorption experiment was conducted using pure liquid nitrogen as the adsorption medium (-196 &amp;deg; C).&amp;nbsp;Raman testing was conducted on a Horiba evolution Raman spectrometer, with an excitation wavelength of 532 nm and a scanning range of 100-1100 cm-1.&amp;nbsp;Fourier transform infrared spectroscopy (FT-IR) was performed on Bruker Tensor 27, using KBr to scan the background. Place the catalyst into the sample cell, with Ar as the carrier gas, raise the temperature to 200 &amp;deg; C, maintain the temperature for 1 hour, and then lower it to the test temperature for testing.&amp;nbsp;X-ray photoelectron spectroscopy (XPS) characterization was performed on Thermo Fisher's ESCALAB 250xi X-ray photoelectron spectroscopy, with a particle source of A1 K &amp;alpha; (hv=1486.6 eV), use the binding energy of C1s (284.6 eV) to compare and correct with the measured element.&amp;nbsp;</dc:description>
  <dc:subject>XRD; BET; Raman; FT-IR; XPS; NH3-TPD; H2-TPR</dc:subject>
  <dc:creator>wang jia</dc:creator>
  <dc:creator>Gao Xiujuan</dc:creator>
  <dc:creator>Song Faen</dc:creator>
  <dc:creator>Zhang Junfeng</dc:creator>
  <dc:creator>Wang Xiaoxing</dc:creator>
  <dc:creator>Zhang Tao</dc:creator>
  <dc:creator>Tan Yisheng</dc:creator>
  <dc:creator>Han Yizhuo</dc:creator>
  <dc:creator>Zhang Qingde</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/publicdomain/zero/1.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1016/s1872-5813(23)60370-6</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>