<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T11:47:42Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.08276" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.08276</identifier>
    <datestamp>2024-10-22T10:27:24Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2024-10-22</dc:date>
  <dc:title>Changes in atmospheric gaseous elemental mercury concentrations and isotopic compositions at Mt. Changbai during 2015-2021 and Mt. Ailao during 2017-2021 in China</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.08276</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This dataset is associated with the manuscript published in     - : Changes in atmospheric gaseous elemental mercury concentrations and isotopic compositions at Mt. Changbai during 2015-2021 and Mt. Ailao during 2017-2021 in China. This dataset includes all the measured data used in the paper.Methodology1.&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;Site locations: Mt. Changbai (MCB, 128.113&amp;deg; E, 42.400&amp;deg; N, 741 m a.s.l.) is located northeastern China. Mt. Ailao (MAL, 101.020&amp;deg; E, 24.533&amp;deg; N, 2450 m a.s.l.) is located in southwestern China. These two sites are regional background sites without strong point mercury sources around the sampling sites.2.&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;Monthly mean GEM (gaseous elemental mercury) concentrations in the atmosphere: GEM concentrations (in ng m-3) were measured using Tekran 2537 mercury vapor analyzers at an interval of 5 min. 5-min GEM concentrations were averaged to hourly mean concentrations and further used to calculate the monthly mean GEM concentrations, which are used for the discussions throughout the manuscript.&amp;nbsp;3.&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;&amp;nbsp;GEM (gaseous elemental mercury) isotopic composition and analytical uncertainty: GEM samples in ambient air were collected using chlorine-impregnated activated carbon (CLC) traps at a flow rate of 2.0-2.5 L min-1. GEM in CLC traps were then pre-concentrated into mixing acid trapping solutions (2HNO3/1HCl, v/v, 5 mL). Isotope ratios of Hg in trapping solutions were measured using cold vapor-multicollector inductively coupled plasma mass spectrometry (CV-MC-ICPMS, Nu Instruments, U.K.). Mass dependent fractionation signatures (&amp;delta;199Hg, &amp;delta;200Hg, &amp;delta;201Hg, &amp;delta;202Hg, &amp;delta;204Hg, in &amp;permil;) were calculated as follows:&amp;delta;xxxHg = [(xxxHg/198Hg)sample/(xxxHg/198Hg)Nist 3133 - 1] &amp;times; 1000&amp;permil; (1)where xxxHg represents the mercury stable isotopes (199Hg, 200Hg, 201Hg, 202Hg, and 204Hg). NIST 3133 refers to bracketing NIST (National Institute of Standards &amp;amp; Technology) SRM (Standard Reference Material) 3133 mercury standard solution, of which the mercury isotope ratios were measured before and after the sample collection to correct the mass bias of MC-ICPMS. MIF signatures (&amp;Delta;199Hg, &amp;Delta;200Hg, &amp;Delta;201Hg, and &amp;Delta;204Hg, in &amp;permil;) were calculated based on the Kinetic MDF law as follows:&amp;Delta;xxxHg = &amp;delta;xxxHg - (&amp;beta;xxx &amp;times;&amp;delta;202Hg) (2)where &amp;beta;xxx is 0.252, 0.5024, 0.752, and 1.493 for 199Hg, 200Hg, 201Hg, and 204Hg, respectively.&amp;nbsp;The 2&amp;sigma; are the 2 times analytical uncertainty of the isotopic compositions, which are the larger 2&amp;sigma; value of either repeated measurements of NIST RM 8610 during the whole analytical sessions or the internal repeated measurements of an individual GEM sample.&amp;nbsp;</dc:description>
  <dc:subject>gaseous elemental mercury; stable mercury isotopes; anthropogenic emissions; source identification; trend analysis</dc:subject>
  <dc:creator>Xian Wu</dc:creator>
  <dc:creator>Xuewu Fu</dc:creator>
  <dc:creator>Hui Zhang</dc:creator>
  <dc:creator>Kaihui Tang</dc:creator>
  <dc:creator>Xun Wang</dc:creator>
  <dc:creator>Hui Zhang</dc:creator>
  <dc:creator>Qianwen Deng</dc:creator>
  <dc:creator>Leiming Zhang</dc:creator>
  <dc:creator>Kaiyun Liu</dc:creator>
  <dc:creator>Qingru Wu</dc:creator>
  <dc:creator>Shuxiao Wang</dc:creator>
  <dc:creator>Xinbin Feng</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>