<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T22:38:33Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.09365" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.09365</identifier>
    <datestamp>2023-07-10T09:08:11Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-07-10</dc:date>
  <dc:title>Original data of the Raman and EDXS analyses of Baideng microbial fossils in Cui et al., 2023</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.09365</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Raman spectra analyses were carried out by use of a Horiba LabRAM Odyssey Raman spectrometer. This system can provide a horizontal resolution of ~1&amp;mu;m and a vertical resolution of ~2&amp;mu;m with use of a &amp;times;100 objective. Raman spectra were excited by a 532 nm green laser with 1%&amp;ndash;10% ND filter (ca. 0.3&amp;ndash;3mW output power) over a ~1&amp;mu;m spot. Single spectrum was baseline-corrected and images of quartz, apatite and Kerogen were acquired in a 20 cm&amp;minus;1 broad spectral window centered at 464 cm&amp;minus;1, 20 cm&amp;minus;1 broad centered at 964 cm&amp;minus;1, 380 cm&amp;minus;1 broad centered at 1470 cm&amp;minus;1, respectively.&amp;nbsp;Energy dispersive X-ray spectroscopy (EDXS) analyses were undertaken by an Oxford instrument X-Max 80 mm2 Silicon Drift Detector equipped on the ThermoFisher Helios G4 UC Focused Ion/Electron Dual Beam system.&amp;nbsp;</dc:description>
  <dc:subject>research data; Raman; SEM-EDXS</dc:subject>
  <dc:creator>Linhao Cui</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1016/j.palaeo.2024.112339</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>