<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T11:46:35Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.10101" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.10101</identifier>
    <datestamp>2023-08-23T11:15:32Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-08-23</dc:date>
  <dc:title>Data Set for Experimental Investigation on Effective Aerosol Scavenging using Different Spray Configurations with Pre-injection of Water Mist for Fukushima Daiichi Decommissioning</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.10101</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>There are 16 Figures submitted in the paper.&amp;nbsp;The first one shows the schematic illustration of mechanisms of aerosol collection by a downward falling spray droplet (made by the drawing software).The second one shows the schematic illustration of agglomeration method for aerosol particles by using water mist (made by the drawing software).The third one shows schematic view of the UTARTS facility (made by the drawing software).The fourth one shows the droplet size distributions measured in the references [20,23].The fifth one shows the schematic views of gas recirculation, accumulated water and water film (made by the drawing software).The sixth one shows the experimental procedures (made by the drawing software).The seventh one shows the mist size distribution for low and high concentration levels given by reference [19].The eleventh and twelveth ones show the calculation results based on Equations in Table 3.The other ones are plotted based on the experimental data measured by WELAS.The uploaded sections here are the figures involved in the eighth, nineth, tenth, thirteenth, fourteenth, fifteenth and sixteenth figures.</dc:description>
  <dc:subject>Fukushima Daiichi decommissioning; Aerosol scavenging; Multiphase flow; Spray system; Aerosol-mist agglomeration</dc:subject>
  <dc:creator>Ruicong Xu</dc:creator>
  <dc:creator>Avadhesh Kumar Sharma</dc:creator>
  <dc:creator>Erdal Ozdemir</dc:creator>
  <dc:creator>Shuichiro Miwa</dc:creator>
  <dc:creator>Shunichi Suzuki</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1007/s41365-024-01401-9</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>