<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T11:47:14Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.23416" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.23416</identifier>
    <datestamp>2025-04-11T14:18:28Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-04-11</dc:date>
  <dc:title>Data for the testing of electrochemical performance and the characterisation of catalysts</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.23416</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Electrochemical experiments were performed in a flow-type electrolytic cell with gas diffusion electrodes and a Nafion 117 proton exchange membrane to isolate the cathode from the anode. A CHI 1140D work station was applied to record the electrochemical responses. The experiments were performed in CO2-saturated 0.5 M KHCO3 solution at ambient temperature and pressure, with a platinum (Pt) foil as the counter electrode and a silver (Ag)/silver chloride (AgCl) electrode filled with a saturated potassium chloride (KCl) solution as the reference electrode.&amp;nbsp;The X-ray diffraction (XRD) spectra were obtained by using a Bruker D8 advance X-ray diffractometer (Karlsruhe, Germany) with a Cu target (&amp;lambda; = 1.54178 &amp;Aring;) selected as the anode target, the scan angle (2&amp;theta;) set at 10-90&amp;deg;, the sweep speed at 2&amp;deg; min-1, and the voltage and current at 40 kV and 40 mA, respectively. X-ray photoelectron spectroscopy (XPS) spectra were recorded using a thermal ESCALAB 250 (ThermoFisher Scientific, Waltham, MA, USA) with an excitation source of Al K&amp;alpha; (h&amp;lambda; = 1486.6 eV). Binding energies were calculated by referencing the C (1s) binding energy of adventitious carbon contamination, which was estimated to be 284.8 eV. Scan electron microscopy (SEM) was executed on a ZEISS Merlin Compact Field Emission Scanning Electron Microscope with an acceleration voltage of 5 kV. Transmission electron microscopy (TEM) and energy-dispersive X-ray spectroscopy (EDS) characterizations were carried out using a Tecani-G2 T20 and F20 operating at an acceleration voltage of 200 kV. High-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM) was employed to visualize Ni single atoms (Ni SACs). The HAADF-STEM images were obtained using a scanning/transmission electron microscope set to 300 kV and outfitted with a probe spherical aberration corrector.</dc:description>
  <dc:subject>CO2 electrocatalytic reduction; high temperature shock method; single atom catalysts; coordination</dc:subject>
  <dc:creator>Peiqi Pang</dc:creator>
  <dc:creator>Changjian Xu</dc:creator>
  <dc:creator>Ruizhu Li</dc:creator>
  <dc:creator>Na Gao</dc:creator>
  <dc:creator>Xianlong Du</dc:creator>
  <dc:creator>Tao Li</dc:creator>
  <dc:creator>Jianqiang Wang</dc:creator>
  <dc:creator>Guoping Xiao</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1016/s1872-5813(25)60549-4</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>