<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T21:08:50Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.29333" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.29333</identifier>
    <datestamp>2026-08-13T15:30:55Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-08-13</dc:date>
  <dc:title>Data from article &amp;quot;Toward to the SERS detection technique of globular analytes: reliability vs sensitivity&amp;quot;</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.29333</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This dataset contains the raw and processed experimental data supporting the manuscript &amp;ldquo;Toward to the SERS detection technique of globular analytes: reliability vs sensitivity&amp;rdquo; submitted to Nanoscale. The data include:1) SEM images of polymer based metal-dielectric resonators. The SEM images were taken with Carl Zeiss Auriga Dual-Beam workstation under normal (high vacuum) mode. Everhart-Thornley Secondary electron detector was used with 200pA e-beam at 20kV landing energy and a working distance of 5.6mm2) AFM images characterizing the surface morphology of the of polymer based metal-dielectric resonators. ;3) SERS&amp;amp;Raman spectra of the polymer based metal-dielectric resonators.The polymer microspheres based metal-dielectric resonators were investigated with unique home-made setup &amp;quot;System for probe-optical 3D correlative microscopy&amp;quot; (IBCh RAS, http://ckp-rf.ru/usu/486825/)&amp;nbsp;&amp;nbsp;combining confocal microspectroscopy 2&amp;amp;3D scanning probe microscopy in a single&amp;nbsp;apparatus10.1016/j.ultramic.2017.06.022.</dc:description>
  <dc:subject>surface-enhanced Raman scattering; localized surface plasmon resonance; metal-dielectric resonators; polystyrene</dc:subject>
  <dc:creator>Konstantin Mochalov</dc:creator>
  <dc:creator>Milena Shestopalova</dc:creator>
  <dc:creator>Denis Korzhov</dc:creator>
  <dc:creator>Andrey Ivanov</dc:creator>
  <dc:creator>Igor Bykov</dc:creator>
  <dc:creator>Konstantin Afanasev</dc:creator>
  <dc:creator>Dmitry Basmanov</dc:creator>
  <dc:creator>Nikita Osipov</dc:creator>
  <dc:creator>Vladimir  Oleinikov</dc:creator>
  <dc:creator>Andrey Sarychev</dc:creator>
  <dc:rights>EMBARGO</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>