<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T13:23:06Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.29509" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.29509</identifier>
    <datestamp>2025-08-27T10:28:19Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-08-27</dc:date>
  <dc:title>Study on the Analytical Method for Beta Counting of Cesium-137 in Fallout</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.29509</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>	[Purpose]:&amp;nbsp;This study aims to establish a reliable beta counting method for cesium-137 detection in fallout samples.&amp;nbsp;[Methods]:&amp;nbsp;Researchers conducted a series of experiments, including digestion system selection experiment, phosphomolybdic acid ammonium adsorption system selection experiment, nitric acid-ammonium chloride detergent substitution experiment, and interference elimination experiment. Referring to the instrument scale and cesium iodobismuthate precipitation source preparation method in HJ 816-2016, and combining with low-background alpha/beta measuring instruments for sample measurement, a beta counting method suitable for cesium-137 in fallout was established.&amp;nbsp;[Results]:&amp;nbsp;Comparative analysis with the GB/T 16145-2022 method showed no significant differences in sedimentation sample detection. Validation experiments demonstrated that the method met precision (relative deviation of parallel samples &amp;le;30%) and accuracy (The recovery rate of spiked samples was 80%~120%) requirements specified in HJ 61-2021.&amp;nbsp;[Conclusion]:&amp;nbsp;Experimental results demonstrate the viability of the beta counting method for cesium-137 in fallout samples developed through this research,Meanwhile, the research results can provide technical references for the construction of relevant standard systems.&amp;zwnj;</dc:description>
  <dc:subject>Cesium-137; Fallout; Beta counting method</dc:subject>
  <dc:creator>Zhen Liying</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>