<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-11T10:25:38Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.32375" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.32375</identifier>
    <datestamp>2025-12-04T19:30:04Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-12-04</dc:date>
  <dc:title>Data for parametrizing alternating current stimulation for neuromodulation</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.32375</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Data collected using a 4x4 multielectrode array (Microprobes) in propofol anesthetized rats receiving subcutaneous alternating current stimulation.Recording electrodes had platinum iridium shanks with a tip width of 125&amp;mu;m, an impedance of 0.4 MOhm, and were spaced 0.5mm apart in the lateral plane. An additional shank with 10 kOhm impedance served as a reference. Electrodes were inserted ~300&amp;mu;m into the craniotomy exposed sensorimotor cortex (L2/3). Data was acquired with a sampling rate of 24 kHz (Tucker-Davis Technologies).Stimulation electrodes were adhered directly to the skull, medial and lateral the cranial window.There are two data files. The first contains experiments where 9 three-month old Sprague-Dawley rats received a randomized order of stimulation parameters (frequencies: 5, 10, 20, 40, and 140 Hz, amplitudes: 50, 100, 200, and 400 &amp;mu;A). Each dated folder contains recordings for a single rat, with subfolders for each stimulation parameter delivery (1-min baseline + 1-min sACS + 1-min baseline).The second data file contains experiments where 13 rats received a single 20-min delivery of 40 Hz, 100 &amp;mu;A stimulation. Each dated folder contains experiments from a single rat. Baseline activity was recorded for 20-min before stimulation onset and subsequently following sACS for 10 minutes. Additional subfolders contain further 20-min of post stimulation baseline activity, collected to an hour following stimulation offset.</dc:description>
  <dc:subject>electrophysiology; neuromodulation; alternating current stimulation ; tACS</dc:subject>
  <dc:creator>Monica Bell Vila</dc:creator>
  <dc:creator>Koletar Margaret</dc:creator>
  <dc:creator>Dorr Adrienne</dc:creator>
  <dc:creator>Trevisiol Andrea</dc:creator>
  <dc:creator>Goubran Maged</dc:creator>
  <dc:creator>Sled John</dc:creator>
  <dc:creator>Bazzigaluppi Paolo</dc:creator>
  <dc:creator>Stefanovic Bojana</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/publicdomain/zero/1.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1162/imag.a.1066</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>