<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T11:30:48Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.34166" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.34166</identifier>
    <datestamp>2025-12-30T13:51:19Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-12-30</dc:date>
  <dc:title>Schedule 1Trace element compositions (&amp;times;10-6) and characteristic parameters of scheelite in Longshan Sb-Au-(W) deposit and Caojiaba W deposit</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.34166</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>In this study, the scheelite samples LS-7-1 and LS-2-1 from the Longshan Sb Au - (W) deposit were collected from the 819 line of the 270 middle section of vein 7, respectively&amp;nbsp;The 210 line vein in the middle section of vein 70 and vein 2, and the sample of Caojiaba W deposit were collected from core 281 m of borehole ZK801. The laser ablation system used for in-situ LA-ICP-MS analysis of scheelite is the GeoLasPro 193 nm ArF excimer laser. During the laser ablation process, helium carrier gas and argon gas are used as carriers&amp;nbsp;Compensate gas and add a small amount of nitrogen to improve sensitivity, and mix the three through a T-shaped joint before entering the ICP. The sample compartment is standard equipment&amp;nbsp;Erosion pool, in which resin molds are added to obtain a smaller sampling space to reduce memory effects and improve flushing efficiency. Single sample&amp;nbsp;The signal acquisition includes 20 seconds of blank signal, 30 seconds of sampling time, and 40 seconds of signal attenuation to background value. During the analysis process, laser&amp;nbsp;The working parameters are a frequency of 5 Hz, an energy density of 3 J/cm2, and a beam spot of 44 &amp;mu; m. Perform ICP-MS performance using SRM612 before testing&amp;nbsp;Optimize the instrument to achieve optimal sensitivity and ionization efficiency (U/Th &amp;asymp; 1), and minimize oxide yield (ThO/Th&amp;lt;0.3%)&amp;nbsp;And low background values. The software ICPMSDataCal is used to select samples and blank signals, calibrate instrument sensitivity, and determine element content&amp;nbsp;Quantity calculation. The correction of trace elements in scheelite is quantitatively calculated using Ca as an internal standard, and NIST 612 is used for quality monitoring.&amp;nbsp;&amp;nbsp;</dc:description>
  <dc:subject>scheelite; LA-ICP-MS; trace element</dc:subject>
  <dc:creator>Huang Jingang</dc:creator>
  <dc:creator>Fu Shanling</dc:creator>
  <dc:creator>Liu Biao</dc:creator>
  <dc:creator>Kong Hua</dc:creator>
  <dc:creator>Hou Xianan</dc:creator>
  <dc:creator>Jiang Hua</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>