<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-11T14:54:17Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.35014" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.35014</identifier>
    <datestamp>2026-01-13T17:05:45Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-01-13</dc:date>
  <dc:title>Influence of Low Al/Tm Ratio on Spectroscopic Properties and Color Centers in Thulium-Doped Silica Glasses</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.35014</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>The main tests involved in this data include: density measurement using an electronic density tester (SD-200L) based on the Archimedes method, and refractive index measurement using a waveguide prism coupling instrument (2010/M). Inductively coupled plasma atomic emission spectroscopy (ICP-AES) was used to measure the actual Tm and Al element content in glass samples. The absorption spectrum was tested using a spectrophotometer (Perkin Elmer Lambda 950) with a wavelength range of 200-2000 nm, a scanning step size of 1 nm, and a glass thickness of 2 mm. The fluorescence spectrum of the glass sample was tested using a high-resolution fluorescence spectrometer (FLS920) with an excitation source of 793 nm laser diode. The fluorescence lifetime decay curve was tested using FLS1000 fluorescence spectrometer, with a 793 nm pulse laser as the excitation source and a pulse width of 4 &amp;micro; s. The Fourier transform infrared spectrometer (Nicolet 6700) was used to measure the infrared transmittance spectrum of the glass sample, with a testing range of 400-4000 cm-1. The glass sample was irradiated using an X-ray irradiation system (MultiRad 160) with a total cumulative irradiation dose of 500 Gy and a dose rate of 10 Gy/min. Grind the irradiated glass into powder, take 200 mg of powder sample and test the continuous wave paramagnetic resonance spectrum at room temperature using an X-band EPR spectrometer (Bruker E580) with a testing range of 344-360 mT. Use a Bruker Avance III HD 500 MHz nuclear magnetic resonance spectrometer to test the 27Al MAS-NMR spectrum, using a 4mm Bruker magic angle rotation (MAS) probe with a resonance frequency of 130.4 MHz and a rotation frequency of 12 kHz. The 10 &amp;deg; pulse length is 0.72 &amp;micro; s, and the relaxation time is 2 s. The chemical shift of the 27Al spectrum is calibrated with a 1 mol/L Al (NO3) 2O3 solution.&amp;nbsp;</dc:description>
  <dc:subject>Thulium-doped silica glass; Low Al/Tm ratio; Spectroscopic properties; Color centers</dc:subject>
  <dc:creator>Han Liping</dc:creator>
  <dc:creator>Zhang Nibo</dc:creator>
  <dc:creator>Zhu Yiming</dc:creator>
  <dc:creator>Li Xin</dc:creator>
  <dc:creator>Guo Mengting</dc:creator>
  <dc:creator>Shao Chongyun</dc:creator>
  <dc:creator>Lei Zhang</dc:creator>
  <dc:creator>Wang Meng</dc:creator>
  <dc:creator>Wang Fan</dc:creator>
  <dc:creator>Yu Chunlei</dc:creator>
  <dc:creator>Hu Lili</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>