<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-12T10:47:52Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.43293" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.43293</identifier>
    <datestamp>2026-07-29T16:59:06Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-07-29</dc:date>
  <dc:title>Reaction Interface Engineering Enables Gravity-Independent Electrolysis</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.43293</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>FFT and statistical analyses of chronopotentiometric (CP) data.Seven folders contain the FFT and statistical analyses of CP curves obtained from two different electrolyzer configurations: the DMSE electrolyzer and the conventional water electrolysis (CW) electrolyzer. Measurements were performed at electrolyte flow rates of 2, 5, and 20 mL min⁻&amp;sup1; through the electrode chamber. For the CW electrolyzer, the potential fluctuations were further classified into two types: positive potential excursions (&amp;quot;Above&amp;quot;) and negative potential excursions (&amp;quot;Below&amp;quot;). The letter &amp;quot;V&amp;quot; in the folder names indicates that the electrodes were arranged in the vertical orientation.Ohmic resistance analysis.An Excel spreadsheet containing the calculated influence of membrane thickness and central electrolyte thickness on the ohmic resistance of the electrolysis cell.Supplementary videos.Two videos showing the liquid side of the gas diffusion electrode (GDE), illustrating the dynamic gas&amp;ndash;liquid interface during electrolysis. These videos are identical to those provided as supplementary materials for the submitted manuscript.Electrochemical data.The complete electrochemical datasets for water electrolysis using both the DMSE and CW electrolyzers, together with the corresponding processed and analyzed results.</dc:description>
  <dc:subject>GDE;  interface; bubble</dc:subject>
  <dc:creator>Zhiyuan Chen</dc:creator>
  <dc:creator>Deepak Pant</dc:creator>
  <dc:rights>EMBARGO</dc:rights>
  <dc:rights>https://opendatacommons.org/licenses/odbl/1-0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>