<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-15T00:03:17Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.hjs.00182" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.hjs.00182</identifier>
    <datestamp>2024-11-12T16:07:36Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2024-11-12</dc:date>
  <dc:title>Study on the dosimetric effect of respiratory motion on boron neutron capture therapy for lung cancer</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.hjs.00182</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>[Background]: Boron Neutron Capture Therapy (BNCT) is an emerging radiotherapy technique. However, respiratory motion has a critical impact on the dose accuracy in BNCT treatment of lung cancer.&amp;nbsp;[Purpose]: This study aims to quantify the dosimetric impact caused by respiratory motion during BNCT treatment of lung cancer.&amp;nbsp;[Methods]: This study employs the Monte Carlo simulation method to develop a dynamic model capturing the spatiotemporal variations of tumors and organs due to respiratory motion in lung cancer treatment, and performs Monte Carlo dose calculations for BNCT. Firstly, using the Multi-function And Generalized Intelligent Code-bench based on Monte Carlo method (MagicMC), this study modeled the adult male phantom provided by Oak Ridge National Laboratory (ORNL). Then, by incorporating high-order cosine functions that describe respiratory motion, this study established a dynamic dose calculation model. Finally, this study employed MagicMC to calculate the dose errors in tumors and organs resulting from respiratory motion in different directions within three-dimensional space.&amp;nbsp;[Results]: The results indicate that during a respiratory cycle, the tumor in all three motion directions exhibits the largest percentage dose difference at the 50% phase. In the left-right direction(LR), it is 0.310%; in the anterior-posterior direction(AP), it is 5.830%; and in the superior-inferior direction(SI), it is -2.852%. The closer healthy tissues are to the irradiation field, the higher the dose rate they receive. The maximum percentage dose difference for the heart in the LR direction is 2.070%, and the maximum percentage dose differences for the right lung in the AP and SI directions are 4.128% and -11.962%, respectively. During BNCT treatment irradiation, organ motion in the AP direction has the greatest impact on tumor dose, resulting in a dose error of 1.644%. For healthy tissues, the dose errors induced by motion in all three directions remain within &amp;plusmn;4%.&amp;nbsp;[Conclusions]: The study demonstrates that organ respiratory motion during BNCT treatment for lung cancer affects the doses received by tumors and healthy tissues, the calculation results can provide a reference for precise dose calculation and clinical irradiation dose correction in BNCT treatment of lung cancer.  </dc:description>
  <dc:subject>Boron Neutron Capture Therapy; Monte Carlo; Dose calculation; Respiratory movement</dc:subject>
  <dc:creator>zhu lin</dc:creator>
  <dc:creator>Yu Tao</dc:creator>
  <dc:creator>Sun Aikou</dc:creator>
  <dc:creator>Gao Kekun</dc:creator>
  <dc:creator>鸿宇</dc:creator>
  <dc:creator>Liu Tong</dc:creator>
  <dc:creator>Wang Song</dc:creator>
  <dc:creator>Zhang Zizhu</dc:creator>
  <dc:creator>Chong Yizheng</dc:creator>
  <dc:creator>Chen Zhenping</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>