<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T07:19:40Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.hjs.00306" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.hjs.00306</identifier>
    <datestamp>2025-02-28T09:02:17Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-02-28</dc:date>
  <dc:title>The impact of source-to-film distance on the accuracy of beta-ray surface density measurement</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.hjs.00306</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>[Background] The beta-ray surface density measurement instrument is widely used for the online measurement of the surface density of electrode sheets in the coating process of lithium batteries. A significant measurement error was observed when the source-to-film distance (SFD) varied under fixed source-to-detector distance (SDD). [Purpose] This study aims to investigate and minimize the impact of SFD variations on the accuracy of beta-ray surface density measurements. [Methods]First, experimental tests were conducted using the beta-ray surface density measurement device with a fixed SDD to quantify the influence of SFD changes (4&amp;ndash;8 mm) on copper film surface density measurements. Second, Geant4 Monte Carlo simulations were performed to model beta-ray scattering effects under three collimator configurations: detector-side single collimator, source-side single collimator, and dual collimators. Finally, the optimized source-side single collimator geometry was experimentally validated by reproducing SFD variations and recalculating measurement deviations. [Results]Initial experimental measurements revealed that 1 mm SFD variation caused a maximum measurement deviation of 13.3% in surface density values. Monte Carlo simulations demonstrated that the source-side single collimator configuration minimized scattering effects, showing the smallest mean absolute deviation among all three geometries tested. Experimental validation confirmed this improvement, with the maximum deviation decreasing from 13.3% to 3.5% after device optimization. [Conclusions]By adopting a source-side single collimator, the study achieved a 73.7% reduction in measurement error caused by SFD variations, providing a practical solution for enhancing online surface density measurement accuracy in lithium battery production.</dc:description>
  <dc:subject>beta-ray; surface density measurement; source-to-film distance; Monte Carlo simulation</dc:subject>
  <dc:creator>Han Bing</dc:creator>
  <dc:creator>Zuo Jingxin</dc:creator>
  <dc:creator>Bai Lixin</dc:creator>
  <dc:creator>Liang Yongfei</dc:creator>
  <dc:creator>Yang Chaowen</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nd/4.0</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1093/med/9780198795483.003.0004</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>