<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T11:00:55Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.hjs.00494" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.hjs.00494</identifier>
    <datestamp>2025-07-15T09:47:39Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-07-15</dc:date>
  <dc:title>Radiation Shielding Design and Residual Radioactivity Assessment for the Beam Dump at XiPAF</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.hjs.00494</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>[Background] The Xi'an 200MeV proton application facility (XiPAF) was constructed as an accelerator facility for the study of single-event effects on aerospace devices. Recently, XiPAF has been planned for upgrade and transformation into a versatile experimental facility for both proton and heavy-ion applications. [Purpose] This study aims to develop a radiation-safe beam dump design ensuring compliance with operational dose limits during operation and minimizing post-irradiation residual doses.&amp;nbsp;[Methods]Based on Monte Carlo simulations using FLUKA, a composite structure beam dump was designed with polyethylene as the target core material, which leaded a low neutron yield. Shielding performance was quantified via ambient dose equivalent rate (H*(10)) mapping at critical locations. Residual dose decay kinetics were modeled for three operational scenarios: 1-hour, 1-day, and 1-week continuous irradiation. [Results] The computational results show that the ambient dose equivalent rate at the rear and transverse sides of the beam dump is 4.2 mSv/h and 3.2 mSv/h (below the 5.5mSv/h limit), respectively. Compared to traditional graphite core, polyethylene demonstrated about 75% lower upstream dose while maintaining equivalent shielding performance. Analysis of residual dose under the three operational scenarios&amp;nbsp;&amp;nbsp;showed consistent decay patterns reaching the dose constraint of 2.5&amp;mu;Sv/h after 2-3 hours cooling time.&amp;nbsp;[Conclusions]The results provide practical reference for radiation protection design of beam dumps at similar intermediate-energy proton accelerator facilities.</dc:description>
  <dc:subject>Beam dump; Radiation shielding; Radioactivity; Monte-Carlo</dc:subject>
  <dc:creator>wang di</dc:creator>
  <dc:creator>Wang Zhongming</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>