<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T07:17:47Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.hjs.00543" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.hjs.00543</identifier>
    <datestamp>2025-11-11T10:13:01Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-11-11</dc:date>
  <dc:title>X-Ray Absorption Multi-edge Analysis method for simultaneous determination of U and Pu in Solution</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.hjs.00543</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>[Background]: Determination of Uranium abd Plutonium in fast reactor spent fuel reprocessing is vital for the quantity control of process and products. [Purpose]: This study aims to establish an non-destructive analytical method for simultaneous determination of Uranium and Plutonium. [Methods]: X-Ray absorption spectrum method based on K-edge or L-edge of U and Pu were developed respectively. After obtaining the spectra of standard mixture solutions of U and Pu, a standard data process for mathematical model based on multivariate linear fitting method was established. Finally, measurements were conducted on samples to evaluate the stability and accuracy of the mothod. [Results]: Within the concentration range of 20 to 100 g/L for Uranium and 10 to 40 g/L for Plutonium, the result shows the relative deviation of measurement results is better than 5%. The precision of Uranium was better than 3% which could be better than 1% with higher concentration, and the precision of Plutonium was better than 4%. [Conclusions]: The established method can be used for the quantitative analysis of Uranium and Plutonium with good measurement accuracy and repeatability and could be used in practice.</dc:description>
  <dc:subject>Multi-edge; X-Ray Absorption; Simultaneous Determination of Uranium and Plutonium</dc:subject>
  <dc:creator>熊超杰</dc:creator>
  <dc:creator>康海英</dc:creator>
  <dc:creator>郑维明</dc:creator>
  <dc:creator>朱海巧</dc:creator>
  <dc:creator>吴玉龙</dc:creator>
  <dc:creator>左臣</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>