<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T10:58:37Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.hjs.00601" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.hjs.00601</identifier>
    <datestamp>2026-01-16T15:03:40Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-01-16</dc:date>
  <dc:title>Trace U/Th in Copper by ICP-MS: Sample/Blank Results and k-Coefficient Dataset</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.hjs.00601</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This dataset supports the manuscript &amp;ldquo;Trace Uranium and Thorium Determination in Copper Samples by ICP-MS&amp;rdquo;. It provides three processed, plot-ready tables used to reproduce the key numerical results and figures in the paper:(1) Sample results: concentrations of ^232Th and ^238U for two copper samples measured under different dilution conditions (reported as mean &amp;plusmn; statistical uncertainty, unit: pg&amp;middot;g⁻&amp;sup1;);(2) Blank results: procedural blank results obtained following the same workflow (mean &amp;plusmn; statistical uncertainty, unit: pg&amp;middot;g⁻&amp;sup1;);(3) k-coefficient data: correction coefficient k as a function of measurement order under different magnification/dilution settings, enabling correction of systematic bias in repeated measurements and direct re-plotting of the corresponding curve(s) in the paper.The dataset is intended for rapid figure/table reproduction and for facilitating future comparisons or overlaying new data on the same plotting framework.</dc:description>
  <dc:subject>ICP-MS; Uranium; Thorium; Copper</dc:subject>
  <dc:creator>liu wu jun zhe</dc:creator>
  <dc:creator>Wang Siguang</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>