<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-12T16:17:41Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00009" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00009</identifier>
    <datestamp>2023-02-08T08:00:00Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-02-08</dc:date>
  <dc:title>Raw Data of &amp;quot;Assessment of the induced radioactivity in the treatment room of the Heavy Ion Medical Machine in Wuwei using PHITS&amp;quot;</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00009</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This data set is the original data generated during the study of induced radioactivity level in heavy ion radiotherapy treatment room with Phits, which itself is used to form the chart of the paper and support the research conclusion of the paper. A total of 39 files are included, all generated directly by running the Phits program.You can go to Phits official website to apply for download. (https://phits.jaea.go.jp)Data relating to air activation analysis：tdchain_air.act, tdchain_air.angData relating to phantom activation analysis: point-dose_xyz-src_t1.out, point-dose_xyz-src_t2.out, point-dose_xyz-src_t3.out, point-dose_xyz-src_t4.out, point-dose_xyz-src_t5.out, point-dose_xyz-src_t6.out, point-dose_xyz-src_t7.out, point-dose_xyz-src_t8.out, point-dose_xyz-src_t9.out, point-dose_xyz-src_t10.out, point-dose_xyz-src_t11.out, point-dose_xyz-src_t12.out, point-dose_xyz-src_t13.out, point-dose_xyz-src_t14.out, point-dose_xyz-src_t15.out, point-dose_xyz-src_t16.out, point-dose_xyz-src_t17.out, tdchain_water.act, tdchain_water_gamma_t1.pht, tdchain_water_gamma_t2.pht, tdchain_water_gamma_t3.pht, tdchain_water_gamma_t4.pht, tdchain_water_gamma_t5.pht, tdchain_water_gamma_t6.pht, tdchain_water_gamma_t7.pht, tdchain_water_gamma_t8.pht, tdchain_water_gamma_t9.pht, tdchain_water_gamma_t10.pht, tdchain_water_gamma_t11.pht, tdchain_water_gamma_t12.pht, tdchain_water_gamma_t13.pht, tdchain_water_gamma_t14.pht, tdchain_water_gamma_t15.pht, tdchain_water_gamma_t16.pht, tdchain_water_gamma_t17.phtData relating to activation analysis of beam line components: tdchain_non-fixed.act, tdchain_fixed.act</dc:description>
  <dc:subject>Phits; Monte Carlo; Induced radioactivity</dc:subject>
  <dc:creator>Zhong-Ying Dai</dc:creator>
  <dc:creator>Ying Luo</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/https://doi.org/10.1007/s41365-023-01181-8</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>