<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T17:05:17Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00139" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00139</identifier>
    <datestamp>2023-07-11T08:48:00Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-07-11</dc:date>
  <dc:title>Data about the measurement of the cavity-loaded quality factor in superconducting radio-frequency system</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00139</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>In CSV data files, the&amp;nbsp;first column&amp;nbsp;and second&amp;nbsp;column represent the&amp;nbsp;amplitude and phase of cavity pick-up signals respectively; the&amp;nbsp;third column&amp;nbsp;and fourth&amp;nbsp;column represent the&amp;nbsp;amplitude and phase of cavity reference signals respectively; the&amp;nbsp;fifth column&amp;nbsp;and sixth&amp;nbsp;column represent the&amp;nbsp;amplitude and phase of cavity forward signals respectively the&amp;nbsp;seventh column and eighth column&amp;nbsp;represent the&amp;nbsp;amplitude and phase of cavity reflected signals respectively; The data sampling rate is 1.04 MHz.The data files of CM3 directory is the data of CM3-3 cavity befroe and after RF power is turned off.The data files of CM33_Tuner directory is the data of CM3-3 cavity frequency was tuned using a frequency tuner.The data files of CM33_SG directory is the data of CM3-3 cavity frequency was tuned by scanning the frequency of the signal generator.The data files of CM34 directory is the data of CM3-4 cavity data.</dc:description>
  <dc:subject>cavity-loaded quality factor; measurement; superconducting radio-frequency system</dc:subject>
  <dc:creator>Jinying Ma</dc:creator>
  <dc:creator>Chengye Xu</dc:creator>
  <dc:creator>Andong Wu</dc:creator>
  <dc:creator>Guodong Jiang</dc:creator>
  <dc:creator>Yue Tao</dc:creator>
  <dc:creator>Zongheng Xue</dc:creator>
  <dc:creator>Longbo Shi</dc:creator>
  <dc:creator>Tiancai Jiang</dc:creator>
  <dc:creator>Zhenglong Zhu</dc:creator>
  <dc:creator>Ziqin Yang</dc:creator>
  <dc:creator>Zheng Gao</dc:creator>
  <dc:creator>Liepeng Sun</dc:creator>
  <dc:creator>Guirong Huang</dc:creator>
  <dc:creator>Feng Qiu</dc:creator>
  <dc:creator>Yuan He</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1007/s41365-023-01281-5</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>