<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T23:19:37Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00277" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00277</identifier>
    <datestamp>2023-10-08T08:53:42Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2023-10-08</dc:date>
  <dc:title>Data support of 《Design and performance of a high-speed and low-noise preamplifier for SiPM》</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00277</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Considering the R&amp;amp;D for upgrading the K0 L and &amp;micro; detectors in the Belle II experiment using a scintillator and silicon photomultiplier (SiPM), we designed a compact high-speed and low-noise preamplifier. The preamplifier demonstrated a good gain stability, bandwidth of 426 MHz, baseline noise level of &amp;sigma; &amp;asymp; 0.6 mV, dynamic range of up to 170 mV of the input signal amplitude, good time resolution of 20 ps, and it can be comprehensively applied to SiPMs. Adopting pole-zero-cancellation in the preamplifier reduces both the rise and fall times of the SiPM signal, which can significantly improve the time resolution and reduce the pile-up when using a large SiPM or an array of SiPMs. Various combinations of the preamplifier and several types of SiPMs demonstrated time resolutions better than 50 ps for most cases; when the number of detected photons was larger than 60, a time resolution of approximately 25 ps was achieved.</dc:description>
  <dc:subject>Silicon photomultiplier; High-speed amplifier; Low noise; High time resolution</dc:subject>
  <dc:creator>Xiyang Wang</dc:creator>
  <dc:creator>Hongyu Zhang</dc:creator>
  <dc:creator>Deqing Fang</dc:creator>
  <dc:creator>Wanbing He</dc:creator>
  <dc:creator>Xiaolong Wang</dc:creator>
  <dc:creator>Qibin Zheng</dc:creator>
  <dc:creator>Shiming Zou</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1007/s41365-023-01328-7</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>