<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-15T00:18:00Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00354" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00354</identifier>
    <datestamp>2024-09-30T09:43:22Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2024-09-30</dc:date>
  <dc:title>Data for Identification algorithm of low-count energy spectra under short-duration measurement based on heterogeneous sample transfer</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00354</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Measurement experiments in this study employed the AT6104DM spectrometer by Atomtex. The detection unit, enclosed within a seismic-resistant and waterproof stainless steel container, utilized a NaI(TI) crystal measuring &amp;Oslash;63x63mm to record gamma radiation from controlled radionuclides, exhibiting a typical resolution of 7.5\% at 662keV (${ }^{137}\mathrm{Cs}$). Detection energy range of the spectrometer spanned from 70keV to 3MeV.&amp;nbsp;Measurement experiments were conducted in a laboratory setting. A specific open area within the laboratory was chosen as a fixed point. A ruler was placed on the ground, with the radiation source positioned at the origin of the ruler. The spectrometer was then moved to alter variables such as the relative distance from the source and the measurement angle. Two V-type radiation sources, ${ }^{137} \mathrm{Cs}$ and ${ }^{60}\mathrm{Co}$, as well as one IV-type radiation source, ${ }^{152}\mathrm{Eu}$, were utilized in the measurements, with activities of $3.7\times10^5$ Bq, $3.7\times10^5$ Bq, and $3.7\times10^8$ Bq, respectively. To investigate the proposed method's accuracy in identifying isotopes under shorter measurement times, the measurement duration was limited to 1 second to 5 seconds.</dc:description>
  <dc:subject>Cs-137; AT6104DM spectrometer; Co-60; Eu-152</dc:subject>
  <dc:creator>刘灏霖</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by-nc/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/https://doi.org/10.1007/s41365-024-01595-y</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>