<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T12:05:26Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00569" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00569</identifier>
    <datestamp>2025-02-14T11:34:49Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-02-14</dc:date>
  <dc:title>10,000 Sets of Neutron Time-of-Flight (ToF) Signals from a Photoneutron Source Driven by an 8 ps Pulsed 45 MeV Electron Beam</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00569</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This dataset is derived from neutron Time-of-Flight (ToF) measurements conducted using a photoneutron source powered by an 8 picosecond (ps) pulsed 45 MeV electron beam. The experiment was performed at the accelerator laboratory of Tsinghua University, where an ultra-short pulsed electron linear accelerator (e-LINAC) was utilized to generate electron beam pulses. These pulses were directed at a tantalum (Ta) target (&amp;phi;20 mm &amp;times; 16 mm cylinder) positioned approximately 2 cm in front of the e-LINAC Ti window. The interaction between the electron beam and the Ta-target facilitated the conversion of electrons to neutrons via the e&amp;rarr;&amp;gamma;&amp;rarr;n process, producing a continuous neutron energy spectrum ranging from sub-keV levels to over 10 MeV. The neutron-beam intensity reached up to 1.925 &amp;times; 10^8 n/s, with an electron intensity of 0.7 nC/pulse at a repetition rate of 10 Hz.The ToF measurements were conducted over a distance of 5 meters using a neutron detection system comprising a &amp;phi;100 mm &amp;times; 100 mm EJ299-33A plastic scintillator coupled with a Hamamatsu R13089 photomultiplier tube (PMT). Neutron signals were acquired using a LeCroy WaveRunner 64 Mix 600 MHz oscilloscope with a sampling rate of 2.5 Giga-samples per second (Gs/s). Data acquisition was synchronized with the e-LINAC and controlled via a computer connected through the TCP/IP protocol. Offline data processing employed constant fraction timing to accurately determine the arrival times of photons or neutrons.</dc:description>
  <dc:subject>compressed sampling; neutron ToF signal; MATLAB</dc:subject>
  <dc:creator>wangqibiao</dc:creator>
  <dc:creator>Deng Chao</dc:creator>
  <dc:creator>Wang Shujun</dc:creator>
  <dc:creator>Hu Qin</dc:creator>
  <dc:creator>Tang Yinghong</dc:creator>
  <dc:creator>Li Pengcheng</dc:creator>
  <dc:creator>Xie Bo</dc:creator>
  <dc:creator>Yang Jianbo</dc:creator>
  <dc:creator>Tuo Xianguo</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/licenses/by/4.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/https://doi.org/10.1007/s41365-025-01669-5</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>