<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-12T13:52:15Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00709" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00709</identifier>
    <datestamp>2025-05-07T20:09:45Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-05-07</dc:date>
  <dc:title>Saturation Effect Study and Ion Recombination Correction on Ionization Chamber for Ultra-high Dose Rate (FLASH) of Carbon Ions</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00709</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Background and Purpose: The ionization chamber produces significant space-charge and ion recombination&amp;nbsp;effects at ultra-high dose rates, posing a challenge for dose monitoring. In addition, there is no generally ac-&amp;nbsp;cepted ion correction model for dosimetry in FLASH radiotherapy, making it crucial to monitor the dose at&amp;nbsp;ultra-high dose rates accurately and in real time. Methods: In this study, the air pressure of the ionization&amp;nbsp;chamber was reduced to perform real-time beam monitoring, and a Faraday cup was used for calibration for&amp;nbsp;active dosimetry. To study the saturation effect of the ionization chamber, the drift, attachment, recombination,&amp;nbsp;and diffusion processes of the electron-ion pairs were modeled using finite-element analysis based on physi-&amp;nbsp;cal phenomenological principles, and the correction factor was calculated. Results: The experimental results&amp;nbsp;showed that the FLASH ionization chamber measures good dose linearity at a dose rate of approximately 0.2&amp;nbsp;Gy/s. When the air pressure of the chamber was adjusted to 10 mbar, the response of the FLASH ionization&amp;nbsp;chamber was linear at a dose rate of approximately 50 Gy/s, with the residuals within 2 %. Furthermore, by&amp;nbsp;using physical phenomenology to resolve the process of electron-ion pair motion in the sensitive volume of the&amp;nbsp;ionization chamber, the analytical model better describes the saturation effect of carbon ions at ultra-high dose&amp;nbsp;rates. The maximum deviation in the calculated correction factor is less than 10 %. Conclusion: We studied&amp;nbsp;the saturation effect in dose measurement, achieving accurate and fast dose and profile position measurement&amp;nbsp;across different dose rates in a wide range based on the Heavy Ion Research Facility in Lanzhou.&amp;nbsp;</dc:description>
  <dc:subject>ultra-high dose rate; carbon ions; dosimetry; saturation effect; correction factor</dc:subject>
  <dc:creator>xinle</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/https://doi.org/10.1007/s41365-025-01770-9</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>