<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T14:11:26Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00724" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00724</identifier>
    <datestamp>2025-11-21T09:51:55Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-11-21</dc:date>
  <dc:title>Characteristic analysis of anode panel for a ZnO nanowire cold cathode flat-panel X-ray source using Monte Carlo simulations</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00724</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>1、 Data content: X-ray energy spectrum of flat panel source, number of photons generated by flat panel source, photon spatial distribution data, photon angle distribution data, electron energy conversion distribution data, X-ray flux data.&amp;nbsp;2、 Data generation process:&amp;nbsp;1. Flat panel X-ray source energy spectrum: The actual energy spectrum data is measured by an energy spectrometer (X-123CdTe), and the simulated energy spectrum data is output by Geant4.&amp;nbsp;2. Number of photons generated by the flat panel source: simulated output by Geant4.&amp;nbsp;3. Photon spatial distribution data: The spatial position of particles is output by Geant4, and the number of particles in a specific area is counted by dividing the area into regions using MATLAB&amp;nbsp;4. Photon angle distribution: derived from Geant4 simulation;&amp;nbsp;5. Electronic energy conversion distribution data and X-ray flux data: simulated output by Geant4;&amp;nbsp;3、 Tools used: Geant4, Matlab;&amp;nbsp;</dc:description>
  <dc:subject>Flat-panel X-ray source; X-ray spectra; Number of photon ; X-ray spital distribution; X-ray fluence</dc:subject>
  <dc:creator>Xiaoying Zhang</dc:creator>
  <dc:creator>Jiancong Dai</dc:creator>
  <dc:creator>Jun Chen</dc:creator>
  <dc:creator>WangJiang Wu</dc:creator>
  <dc:creator>Yuan Xu</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>