<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T12:26:33Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.j00186.00816" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.j00186.00816</identifier>
    <datestamp>2025-08-12T08:09:06Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-08-12</dc:date>
  <dc:title>Related data for the paper: Response estimation and evaluation of direct-conversion dual-layer perovskite X-ray detectors: a numerical study with a cascaded signal model</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.j00186.00816</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>This dataset contains numerical simulation results analyzing the imaging performance of dual-layer perovskite-based flat-panel X-ray detectors using methylammonium lead iodide (MAPbI₃) as the material. The simulations were conducted using a cascaded linear systems model, evaluating three key metrics:&amp;nbsp;1. Sensitivity, 2.Modulation Transfer Function (MTF), 3. Detective Quantum Efficiency (DQE). The results are stored as multi-dimensional arrays in MATLAB (.mat) files and are categorized based on different detector parameters. Specifically, the data are used to generate Fig. 3-11.&amp;nbsp;1.Sensitivity dataFile naming: Sen_RQA[5/7/9]Mat_PbI3.matKey Variables- Top layer: S1(dim1:spectrum,dim2:Lt/L,dim3:SC or PC,dim4:ElectricField)) - Bottom layer: S2(dim1:spectrum,dim2:Lt/L,dim3:SC or PC,dim4:ElectricField)Dimension description：- dim1=1;- dim2=1,2,3,4,5 corresponds to Lt/L=10%,20%,30%,40%,50%, respectively ;- dim3=1,2 corresponds to SC and PC, respectively;- dim4=1,2,3,4,5 corresponds to F=0.01,0.05,0.1,0.5,1 V/um, respectively.&amp;nbsp;Examples:&amp;nbsp;Fig3(a), plot Sensitivity_vs_F, RQA7, Lt/L:10%-50%, SC	&amp;gt; Load(&amp;lsquo;Sen_RQA7Mat_PbI3.mat&amp;rsquo;)	&amp;gt; plot(F(:),S1(1,j,1,:));%% top layer, j=1,2,3,4,5	&amp;gt; plot(F(:),S2(1,j,1,:));%% bottom layer, j=1,2,3,4,5&amp;nbsp;2.&amp;nbsp;MTF dataFile naming:&amp;nbsp;MTF_RQA5Mat_PbI3.mat, MTF_RQA7Mat_PbI3.mat, MTF_RQA9Mat_PbI3.matKey Variable-Top layer: MTF_t(dim1:frequency,dim2:Lt/L,dim3: ElectricField, dim4:SC or PC) -Bottom layer: MTF_b(dim1:frequency,dim2:Lt/L,dim3: ElectricField, dim4:SC or PC) Dimension description：	- dim1=1:1:100 corresponds to f=1:0.1:10, respectively;	- dim2=1,2,3,4,5 corresponds to Lt/L=10%,20%,30%,40%,50%, respectively; 	- dim3=1,2,3,4,5 corresponds to F=0.01,0.05,0.1,0.5,1 V/um, respectively;	- dim4=1,2 corresponds to SC and PC, respectively	&amp;nbsp;Examples:&amp;nbsp;Fig7(a), plot MTF_vs_frequency, Lt/L=30%, SC, F=0.1 V/um	&amp;gt; Load(&amp;lsquo;MTF_RQA5Mat_PbI3.mat&amp;rsquo;), plot(f(:)./2,MTF_t(:,3,3,1)); %% top layer,RQA5	&amp;gt; Load(&amp;lsquo;MTF_RQA7Mat_PbI3.mat&amp;rsquo;), plot(f(:)./2,MTF_t(:,3,3,1));%% top layer,RQA7	&amp;nbsp;	&amp;gt; Load(&amp;lsquo;MTF_RQA9Mat_PbI3.mat&amp;rsquo;), plot(f(:)./2,MTF_t(:,3,3,1));%% top layer,RQA9&amp;nbsp;3.&amp;nbsp;DQE dataFile naming: DQE_RQA5_D0.1.mat, DQE_RQA5_D1.mat, DQE_RQA7_D0.1.mat, DQE_RQA7_D1.mat, DQE_RQA9_D0.1.mat, DQE_RQA9_D1.matKey Variable- Top layer: dqe_t(dim1:frequency,dim2:Lt/L,dim3: ElectricField, dim4:SC or PC,dim5: eNoise, dim6: dark current) - Bottom layer: dqe_b(dim1:frequency,dim2:Lt/L,dim3: ElectricField, dim4:SC or PC,dim5: eNoise, dim6: dark current) Dimension description：- dim1=1:1:100 corresponds to f=1:0.1:10, respectively;- dim2=1,2,3,4,5 corresponds to Lt/L=10%,20%,30%,40%,50%, respectively; - dim3=1,2,3,4,5 corresponds to F=0.01,0.05,0.1,0.5,1 V/um, respectively;- dim4=1,2 corresponds to SC and PC, respectively;- dim5=1,2,3 corresponds to eNoise=200, 700, 2000e-, respectively;- dim6=1,2,3,4,5, corresponds to dark current eq7.Jd(F))&amp;nbsp;Examples:&amp;nbsp;Fig11(a), plot DQE_vs_frequency, Lt/L=30%, PC, RQA7, F=0.5 V/um, 1uGy	&amp;gt; Load(&amp;lsquo;DQE_RQA7_D1.mat&amp;rsquo;);	&amp;gt; plot(f(:)./2,dqe_t(:,3,4,2,i,4));&amp;nbsp;%% top layer,i =1,2,3	&amp;gt; plot(f(:)./2,dqe_b(:,3,4,2,i,4));&amp;nbsp;%% bottom layer, i=1,2,3</dc:description>
  <dc:subject>perovskite-based; flat-panel X-ray detectors; dual-layer FPD</dc:subject>
  <dc:creator>han cui</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1007/s41365-025-01845-7</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>