<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-13T08:35:03Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.nbsdc.00079" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.nbsdc.00079</identifier>
    <datestamp>2024-09-05T10:26:54Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2024-09-05</dc:date>
  <dc:title>Dataset on interlaminar fracture toughness of wing-feather-inspired fiber-reinforced composites</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.nbsdc.00079</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Mechanical test of Mode I and Mode II Interlaminar fracture toughness (IFT)The sample preparation and tests of GIC and GIIC were according to ASTM D5528-13 and HB7403-96. A standard double-cantilever beam (DCB) specimen with a size of 180 mm (length) &amp;times; 25 mm (width) &amp;times; 3 mm (thickness) was used to measure GIC. The pre-crack made by PVDF film was 50 mm in length. An end notch flexure (ENF) test specimen with 140 mm (length) &amp;times; 25 mm (width) &amp;times; 3 mm (thickness) was used to measure GIIC. The pre-crack made by PVDF film was 40 mm in length.For Mode I test, the sample was clamped on a universal testing machine and was loaded at a rate of 2 mm/min. Critical load (P), displacement of loading point (&amp;delta;) and crack length (a) were recorded during the test. Then the load-displacement curve was plotted. The recorded data was used to calculate GIC. Similarly, for the Mode II test, three-point ENF tests were carried out. The loading rate was 2 mm/min. The load-displacement curve was plotted for further analysis. At least five specimens of each kind of CFRP composites were tested.</dc:description>
  <dc:subject>Composite laminate; Interlaminar toughening; Hierarchical structure </dc:subject>
  <dc:creator>Wenda Song</dc:creator>
  <dc:creator>You Chen</dc:creator>
  <dc:creator>Zhengzhi Mu</dc:creator>
  <dc:creator>Yufei Wang</dc:creator>
  <dc:creator>Zhiyan Zhang</dc:creator>
  <dc:creator>Ze Wang</dc:creator>
  <dc:creator>Linpeng Liu</dc:creator>
  <dc:creator>Binjie Zhang</dc:creator>
  <dc:creator>Yujiao Li</dc:creator>
  <dc:creator>Bo Li</dc:creator>
  <dc:creator>Dashun Zhang</dc:creator>
  <dc:creator>Junqiu Zhang</dc:creator>
  <dc:creator>Shichao Niu</dc:creator>
  <dc:creator>Zhiwu Han</dc:creator>
  <dc:creator>Luquan Ren</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.1016/j.compositesb.2022.109827</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>