<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-11T20:17:50Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.space.02341" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.space.02341</identifier>
    <datestamp>2025-02-12T16:35:01Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-02-12</dc:date>
  <dc:title>Waveform Dataset of Multi-Type, Multi-Energy Charged Particles Collected with a Silicon Detector</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.space.02341</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>We have constructed a high-resolution waveform dataset that contains various types of charged particles at different energy levels. In the actual experiment, ions accelerated by the GIC4117 2 &amp;times; 1.7 MV series accelerator at the Analytical and Testing Center of Beijing Normal University were measured using a semiconductor detector. The detector used was a 300 &amp;micro;m thick ORTEC U-013-150-300 ion-implanted silicon detector. The preamplifier used in the experiment was the CANBERRA 2003BT charge-sensitive preamplifier, which has a very low noise level. The output from this preamplifier is the Timing Output, providing a differential current output that corresponds to particle events. We followed the experimental setup mentioned above to collect waveforms for five types of particles at three energy levels: H (2.5 MeV), B (2.5, 3.75, and 5 MeV), C (2.5 MeV), O (2.5 MeV), and Al (2.5 MeV). The waveform acquisition interval was 0.2 ns per data point. We retained the waveforms starting from the rising edge and recorded them for a duration of 120 ns (600 data points), after which the baseline voltage was removed, forming the dataset.</dc:description>
  <dc:subject>pulse shape analysis; silicon detector; charged particle</dc:subject>
  <dc:creator>Xishuo Mo</dc:creator>
  <dc:creator>Xin Zhang</dc:creator>
  <dc:creator>Chaoping Bai</dc:creator>
  <dc:creator>Ziting Wang</dc:creator>
  <dc:creator>Shuai Zhang</dc:creator>
  <dc:creator>YueQiang Sun</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:relation>http://www.doi.org/10.3390/app15041837</dc:relation>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>