<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T21:38:23Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.space.03032" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.space.03032</identifier>
    <datestamp>2026-02-25T10:51:50Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2026-02-25</dc:date>
  <dc:title>CE7-high energy detector calibration</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.space.03032</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>CE-7 high energy detector calibration information. (1)sensor scale accelerator: sensor scale_x_y_m_n.txt , x represents the sensor name, y represents the number of sensor amplification channels, m represents the particle type, and n represents the accelerator name. The first line of the file is the particle deposition energy, and the second line is the ADC value.(2)sensor scale electronic calibration: sensor scale_x_y_electronic.txt, x represents the sensor name, y represents the number of sensor amplification channels.The first line of the file is the particle deposition energy, and the second line is the ADC value(3)energy resolution: energy resolution_xMeV-y detect.txt.&amp;nbsp;x represents the energy,y represents the particle types.The first line of the file is the particle deposition energy, and the second line is the normalization counts(4)energy resolution distribution:energy resolution distribution_x_y.txt. x represents the sensor name,y represents the number of sensor amplification channels.The first line of the file is the particle deposition energy, and the second line is the energy resolution.(5)sensor response:sensor_x_y_response_m-nMeV.txt. x represents the sensor name, y represents the number of sensor amplification channels, m represents the particle type, and n represents the energy. The first line of the file is the ADC value, and the second line is the normalization counts.</dc:description>
  <dc:subject>accelerator;  lunar surface; highe energy</dc:subject>
  <dc:creator>侯东辉</dc:creator>
  <dc:rights>RESTRICTED</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>