<?xml version="1.0" encoding="UTF-8"?>

<?xml-stylesheet type="text/xsl" href="/static/oaitohtml.xsl"?>

<!--
<?xml-stylesheet type="text/xsl" href="/oaitohtml.xsl"?>
-->

<OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
    <responseDate>2026-10-14T02:27:27Z</responseDate>
    <request verb="GetRecord" metadataPrefix="oai_dc" identifier="10.57760/sciencedb.zhfsyxyfhzz.00548" >https://www.scidb.cn/oai</request>
<GetRecord>
    <record>
    <header >
    <identifier>10.57760/sciencedb.zhfsyxyfhzz.00548</identifier>
    <datestamp>2025-12-18T11:05:54Z</datestamp>
</header>
    <metadata>
        
<oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:date>2025-12-18</dc:date>
  <dc:title>Clinical Value of Ultra-Low-Dose High-Resolution CT Combined with Deep Learning Image Reconstruction in CT-Guided Percutaneous Lung Biopsy</dc:title>
  <dc:identifier>doi:10.57760/sciencedb.zhfsyxyfhzz.00548</dc:identifier>
  <dc:language>en</dc:language>
  <dc:description>Objective To evaluate the effects of ultra-low-dose computed tomography (CT) combined with a 1024 &amp;times; 1024 reconstruction matrix and a deep learning image reconstruction algorithm on image quality and radiation dose in CT-guided percutaneous transthoracic needle biopsy (PTNB).Methods A total of 50 patients who underwent CT-guided thoracic needle biopsy were prospectively enrolled. Multiple repeated local CT scans were performed during the biopsy procedure. Three scanning protocols were applied sequentially: a conventional-dose protocol (Group A: 120 kVp, 180 mA, 512 matrix, ClearView 60%), a low-dose protocol (Group B: 120 kVp with automatic tube current modulation using O-Dose, noise index 1.0, 1024 matrix, ClearInfinity reconstruction at 40%, 60%, and 80%), and an ultra-low-dose protocol (Group C: O-Dose noise index 0.7, 1024 matrix, ClearInfinity reconstruction at 40%, 60%, and 80%). Other scan parameters were kept identical across groups. CT attenuation values and standard deviations (SD) of the ascending aorta and chest wall fat were measured to calculate signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality, including lesion margin delineation, density homogeneity, and artifact severity, was independently assessed using a five-point Likert scale. CT dose index volume (CTDIvol), dose&amp;ndash;length product (DLP), effective dose (ED), and size-specific dose estimate (SSDE) were recorded and analyzed. Intergroup comparisons were performed using one-way ANOVA or non-parametric tests as appropriate.Results Inter-observer agreement for subjective image assessment was good (Kappa=0.705~0.865，P&amp;lt;0.05). Compared with the conventional-dose protocol, CTDIvol and SSDE were reduced by 61.8% and 80.0% in Groups B and C, respectively. In both low- and ultra-low-dose protocols, images reconstructed with ClearInfinity at 60% and 80% demonstrated significantly higher SNR and CNR than those of the conventional protocol (P &amp;lt; 0.05). Image quality reconstructed with ClearInfinity at 60% was comparable to that of the conventional-dose group in terms of lesion margin visibility, density uniformity, and artifact control (P &amp;gt; 0.05) and was superior to other reconstruction strengths within the same dose group.Conclusion With an approximately 80% reduction in radiation dose, high-resolution reconstruction using a 1024 matrix combined with ClearInfinity deep learning reconstruction at 60% strength provides image quality sufficient for CT-guided lung biopsy. This technique represents a safe and feasible imaging solution for ultra-low-dose CT-guided percutaneous lung biopsy.</dc:description>
  <dc:subject>Deep learning image reconstruction; Low-dose CT; Percutaneous transthoracic needle biopsy; Large reconstruction matrix; Image quality; Feasibility</dc:subject>
  <dc:creator>Wenlong.Zhang</dc:creator>
  <dc:creator>Zhuqing.Yuan</dc:creator>
  <dc:creator>Shigeng.Wang</dc:creator>
  <dc:creator>Jian.Jiang</dc:creator>
  <dc:creator>Donghai.Chen</dc:creator>
  <dc:creator>Miao.Zhang</dc:creator>
  <dc:creator>Jiawei.Zhou</dc:creator>
  <dc:creator>Huanyu.Wang</dc:creator>
  <dc:creator>Renwang.Pu</dc:creator>
  <dc:rights>PUBLIC</dc:rights>
  <dc:rights>https://creativecommons.org/publicdomain/zero/1.0/</dc:rights>
  <dc:type>dataset</dc:type>
  <dc:publisher>Science Data Bank</dc:publisher>
</oai_dc:dc>

    </metadata>
</record>
</GetRecord>
</OAI-PMH>